BJRFC - DISPOSABLE LPG FUEL CYLINDER

  • MSDS: BJRFC
  • Manufacturer: MAGNA INDUSTRIES INC
  • Product Name: DISPOSABLE LPG FUEL CYLINDER
  • National Stock Number: 3439-00-542-0531
Product Identification

Product ID:DISPOSABLE LPG FUEL CYLINDER
MSDS Date:01/01/1987
FSC:3439
NIIN:00-542-0531
Kit Part:Y
MSDS Number: BJRFC

Responsible Party
MAGNA INDUSTRIES INC
2201 WEST 110TH STREET
CLEVELAND, OH 44102
US

Emergency Phone: 216-251-3334 OR 800-969-3334

Info Phone: 216-251-7778

Cage: 0AJN5

Contractor
MAGNA INDUSTRIES INC
CLEVELAND, OH 44102 US

Telephone: 216-251-3334 OR 800-969-3334

Cage: 0AJN5

Ingredients

PROPANE

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 95-98%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT; 9192


ETHANE

CAS: 74-84-0

RTECS: KH3800000

Fraction By Weight: 3-5%

ACGIH TLV: ASPHYXIANT 9192


BUTANE

CAS: 106-97-8

RTECS: EJ4200000

Fraction By Weight: 1-3%

OSHA PEL 800 PPM

ACGIH TLV: 800 PPM; 9192


ISOBUTANE

CAS: 75-28-5

RTECS: TZ4300000

Fraction By Weight: 0.1-0.3%

OSHA PEL 1000 PPM

ACGIH TLV: 1000 PPM


METHANE

CAS: 74-82-8

RTECS: PA1490000

Fraction By Weight: 0.1-0.2%

ACGIH TLV: ASPHYXIANT; 9192

Hazards

Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:LIQUID MAY CAUSE "COLD BURNS" TO EYES
& SKIN SIMILAR TO FROSTBITE. INHALATION OF CONCENTRATIONS BELOW
10,000 PPM HAS LITTLE PHYSIOLOGICAL EFFECT. HIGHER CONCENTRATIONS
MAY CAUSE DIZZINESS AND UNCONSCI OUSNESS DUE TO ASPHYXIATION. THERE
ARE NO REPORTED EFFECTS FROM LONG-TERM LOW-LEVEL EXPOSURE.
Explanation of Carcinogenicity:THIS COMPOUND CONTAINS NO INGREDIENTS AT
CONCENTRATIONS OF 0.1% OR GREATER THAT ARE CARCINOGENS OR SUSPECT
CARCINOGENS.
Effects of Overexposure:ABOVE 100,000 PPM; SYMPTOMS OF EXPOSURE MAY
INCLUDE DIZZINESS, STUPOR, AND UNCONSCIOUSNESS. ACGIH CLASSIFIES
PROPANE AS AN ASPHYXIANT. THERE IS NO RECOMMENDED TLV.
Medical Cond Aggravated by Exposure:NONE KNOWN

First Aid

First Aid:EYES: FOR LIQUID CONTACT, FLUSH EYES WITH LUKEWARM WATER FOR
15 MINUTES. GET MEDICAL CARE. SKIN: FOR BURNS FROM LIQUID CONTACT,
IMMEDIATELY PLACE AFFECTED AREA IN LUKEWARM WATER AND KEEP AT THIS
TEMPE RATURE UNTIL CIRCULATION RETURNS OR USEBODYHEAT TO WARM
FROSTBITE AREAS. GET MEDICAL CARE. INHALATION: REMOVE PERSON TO
FRESH AIR. IF NOT BREATHING, GIVE ARTIFICIAL RESPIRATION. GET
MEDICAL CARE.

Fire Fighting

Flash Point Method:CC
Flash Point:=-102.8C, -153.F
Autoignition Temp:=432.2C, 810.F
Lower Limits:2.4
Upper Limits:9.5
Extinguishing Media:USE CARBON DIOXIDE OR DRY CHEMICAL. DO NOT
EXTINGUISH FIRE UNLESS THE SOURCE OF GAS IS TURNED OFF.
Fire Fighting Procedures:WEAR FIRE FIGHTING PROTECTIVE EQUIPMENT AND A
FULL FACED SELF CONTAINED BREATHING APPARATUS. COOL FIRE EXPOSED
CONTAINERS WITH WATER SPRAY. EVACUATE AREA.
Unusual Fire/Explosion Hazard:METAL CYLINDERS REQUIRE COOLING WITH
WATER TO PREVENT FLAME IMPINGEMENT AND THE WEAKENING OF METAL.

Accidental Release

Spill Release Procedures:STOP LEAK IF POSSIBLE. ELIMINATE ALL SOURCES
OF IGNITION. VENTILATE AREA. EVACUATE ALL PERSONNEL. PROPANE IS
HEAVIER THAN AIR AND CAN SETTLE INTO LOW AREAS. REMAIN UPWIND OF
LEAK. PREVENT VAPOR FROM E NTERING INTO SEWER, BASEMENTS OR
CONFINED AREAS.
Neutralizing Agent:NOT APPLICABLE.

Handling

Handling and Storage Precautions:CYLINDERS SHOULD NOT BE DROPPED.
Other Precautions:STORAGE TEMPERATURE SHOULD BE KEPT BELOW 125F.
CYLINDERS MUST NOT BE RECHARGED.

Exposure Controls

Respiratory Protection:SELF-CONTAINED BREATHING APPARATUS WHERE THE
CONCENTRATION OF PROPANE WOULD REDUCE OXYGEN LEVEL BELOW 18% IN
INHALED AIR.
Ventilation:USE EXPLOSION PROOF VENTILATION EQUIPMENT.
Protective Gloves:INSULATED LEATHER GLOVES AS REQUIRED.
Eye Protection:SAFETY GLASSES, GOGGLES OR FACE SHIELD
Other Protective Equipment:NONE NORMALLY REQUIRED.
Work Hygienic Practices:OBSERVE GOOD PERSONAL HYGIENE PRACTICES AND
RECOMMENDED PROCEDURES. USE PROPER CARE WHEN HANDLING AND STORING
CYLINDERS.
Supplemental Safety and Health
REFER TO CGA BULLETIN SB-2 "OXYGEN DEFICIENT ATMOSPHERES".

Chemical Properties

HCC:G2
Boiling Pt:=-42.2C, -44.F
Melt/Freeze Pt:=-187.8C, -306.F
Vapor Pres:1013
Vapor Density:1.52
Spec Gravity:0.51
Evaporation Rate & Reference:RAPID/GAS AT NORMAL COND.
Solubility in Water:MODERATE
Appearance and Odor:COLORLESS LIQUID. ODOR IS SIMILAR TO BOILING
CABBAGE (ETHYL MERCAPTAIN ADDED)
Percent Volatiles by Volume:100

Stability

Stability Indicator/Materials to Avoid:YES
KEEP SEPARATE FROM STRONG OXIDIZING AGENTS. GAS EXPLODES SPONTANEOUSLY
WHEN MIXED WITH CHLORINE DIOXIDE.
Stability Condition to Avoid:HIGH HEAT, OPEN FLAMES AND OTHER SOURCES
OF IGNITION
Hazardous Decomposition Products:CARBON MONOXIDE

Disposal

Waste Disposal Methods:MOVE LEAKY CYLINDER TO OUTDOORS OR VENTILATED
HOOD. ALLOW GAS TO DISCHARGE AT MODERATE RATE. DISPOSAL SHOULD BE
MADE IN ACCORDANCE WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL
LAWS AND REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.